760255144 | Z-3456-LZ-RR-F12BK/8G1/99L/200

Base Product: Z-LZ

  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA
  • Latin America
  • North America

Fiber Indoor/Outdoor cable, Interlocking Armored, LSZH, Gel-Free, 3456 fiber, Singlemode G.657.A2, Rollable Ribbon with 200um Fibers, Feet jacket marking, Black jacket color

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Portfolio CommScope®
Product Type Fiber indoor/outdoor cable
Product Series Z-LZ

General Specifications

Cable Type Ribbon loose tube
Construction Type Armored | Rollable ribbon
Subunit Type Gel-free
Fibers per Ribbon, quantity 12
Jacket Color Black
Jacket Marking Feet
Fibers per Subunit, quantity 576
Total Fiber Count 3456

Dimensions

Buffer Tube/Subunit Diameter 7.5 mm | 0.295 in
Diameter Over Armor 33.7 mm | 1.327 in
Diameter Over Jacket 35.7 mm | 1.406 in

Mechanical Specifications

Minimum Bend Radius, loaded 536 mm | 21.102 in
Minimum Bend Radius, storage coils 536 mm | 21.102 in
Minimum Bend Radius, unloaded 357 mm | 14.055 in
Tensile Load, long term, maximum 800 N | 179.847 lbf
Tensile Load, short term, maximum 2670 N | 600.240 lbf
Compression 22 N/mm | 125.623 lb/in
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 25 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact 4.4 N-m | 38.943 in lb
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7

Optical Specifications

Fiber Type G.657.A2 | G.657.A2, TeraSPEED®

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Cable Qualification Standards ANSI/ICEA S-104-696 | Telcordia GR-20-CORE Issue 4
Environmental Space Low Smoke Zero Halogen (LSZH)
Flame Test Listing NEC OFCR-ST1 (ETL) and c(ETL)
Flame Test Method CSA FT4 | UL 1666 | UL 1685
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penetration Test Method FOTP-82 | IEC 60794-1 F5

Environmental Test Specifications

Cable Freeze -2 °C | 28.4 °F
Cable Freeze Test Method FOTP-98 | IEC 60794-1 F15
Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend -30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

Packaging and Weights

Cable weight 1143 kg/km | 768.061 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ANATEL Compliant

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Portfolio CommScope®
Product Type Fiber indoor/outdoor cable
Product Series Z-LZ

General Specifications

Cable Type Ribbon loose tube
Construction Type Armored | Rollable ribbon
Subunit Type Gel-free
Fibers per Ribbon, quantity 12
Jacket Color Black
Jacket Marking Feet
Fibers per Subunit, quantity 576
Total Fiber Count 3456

Dimensions

Buffer Tube/Subunit Diameter 7.5 mm | 0.295 in
Diameter Over Armor 33.7 mm | 1.327 in
Diameter Over Jacket 35.7 mm | 1.406 in

Mechanical Specifications

Minimum Bend Radius, loaded 536 mm | 21.102 in
Minimum Bend Radius, storage coils 536 mm | 21.102 in
Minimum Bend Radius, unloaded 357 mm | 14.055 in
Tensile Load, long term, maximum 800 N | 179.847 lbf
Tensile Load, short term, maximum 2670 N | 600.240 lbf
Compression 22 N/mm | 125.623 lb/in
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 25 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact 4.4 N-m | 38.943 in lb
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7

Optical Specifications

Fiber Type G.657.A2 | G.657.A2, TeraSPEED®

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Cable Qualification Standards ANSI/ICEA S-104-696 | Telcordia GR-20-CORE Issue 4
Environmental Space Low Smoke Zero Halogen (LSZH)
Flame Test Listing NEC OFCR-ST1 (ETL) and c(ETL)
Flame Test Method CSA FT4 | UL 1666 | UL 1685
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penetration Test Method FOTP-82 | IEC 60794-1 F5

Environmental Test Specifications

Cable Freeze -2 °C | 28.4 °F
Cable Freeze Test Method FOTP-98 | IEC 60794-1 F15
Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend -30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

Packaging and Weights

Cable weight 1143 kg/km | 768.061 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ANATEL Compliant