Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

6-57826-2 | CS24R WHT C5E 4/24 U/UTP CPK 1KFT

Base Product: CS24R

  • Available in:
  • Asia

Copper Cable, category 5e, 4 pair, UTP, 350 MHz, CMR rated, 1000 ft pull-box, white

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Regional Availability Asia
Portfolio NETCONNECT®
Product Type Twisted pair cable
Product Series 520 Series

General Specifications

Product Number 520R
ANSI/TIA Category 5e
Cable Component Type Horizontal
Cable Type U/UTP (unshielded)
Conductor Type, singles Solid
Conductors, quantity 8
Jacket Color White
Pairs, quantity 4
Transmission Standards ANSI/TIA-568.2-D | CENELEC EN 50288-6-1 | ISO/IEC 11801 Class D

Dimensions

Cable Length 304.8 m | 1000 ft
Diameter Over Jacket, nominal 4.699 mm | 0.185 in
Conductor Gauge, singles 24 AWG

Electrical Specifications

Operating Voltage, maximum 80 V
Remote Powering Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A
Safety Voltage Rating 300 V

Electrical Cable Performance

CS
CommScope
Std
Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
Typ
Typical
IL
Insertion Loss (dB/100m)
NEXT
Near End Crosstalk (dB/100m)
ACR
Attenuation to Crosstalk Ratio (dB/100m))
PSNEXT
Power Sum Near End Crosstalk (db/100m)
PSACR
Power Sum Attenuation to Crosstalk Ratio (dB/100m)
ACRF
Attenuation to Crosstalk Ratio - Far End (dB/100m)
PSACRF
Insertion Loss (dB/100m)
RL
Return Loss (dB)
Frequency IL, STD NEXT, STD ACR, STD PSNEXT, STD PSACR, STD ACRF, STD PSACRF, STD RL, STD
1.00 MHz 2.0 65.3 63.3 62.3 60.3 63.8 60.8 20.0
4.00 MHz 4.1 56.3 52.2 53.3 49.2 51.8 48.8 23.0
8.00 MHz 5.8 51.8 46.0 48.8 43.0 45.7 42.7 24.5
10.00 MHz 6.5 50.3 43.8 47.3 40.8 43.8 40.8 25.0
16.00 MHz 8.2 47.2 39.0 44.2 36.0 39.7 36.7 25.0
20.00 MHz 9.3 45.8 36.5 42.8 33.5 37.8 34.8 25.0
25.00 MHz 10.4 44.3 33.9 41.3 30.9 35.8 32.8 24.3
31.25 MHz 11.7 42.9 31.2 39.9 28.2 33.9 30.9 23.6
62.50 MHz 17.0 38.4 21.4 35.4 18.4 27.9 24.9 21.5
100.00 MHz 22.0 35.3 13.3 32.3 10.3 23.8 20.8 20.1

Material Specifications

Conductor Material Bare copper
Insulation Material Polyolefin
Jacket Material PVC

Environmental Specifications

Operating Temperature -20 °C to +60 °C (-4 °F to +140 °F)
Environmental Space Non-plenum

Packaging and Weights

Cable weight 32.740 kg/km | 22 lb/kft
Packaging Type Pull box

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Product Classification

Regional Availability Asia
Portfolio NETCONNECT®
Product Type Twisted pair cable
Product Series 520 Series

General Specifications

Product Number 520R
ANSI/TIA Category 5e
Cable Component Type Horizontal
Cable Type U/UTP (unshielded)
Conductor Type, singles Solid
Conductors, quantity 8
Jacket Color White
Pairs, quantity 4
Transmission Standards ANSI/TIA-568.2-D | CENELEC EN 50288-6-1 | ISO/IEC 11801 Class D

Dimensions

Cable Length 304.8 m | 1000 ft
Diameter Over Jacket, nominal 4.699 mm | 0.185 in
Conductor Gauge, singles 24 AWG

Electrical Specifications

Operating Voltage, maximum 80 V
Remote Powering Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A
Safety Voltage Rating 300 V

Electrical Cable Performance

CS
CommScope
Std
Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
Typ
Typical
IL
Insertion Loss (dB/100m)
NEXT
Near End Crosstalk (dB/100m)
ACR
Attenuation to Crosstalk Ratio (dB/100m))
PSNEXT
Power Sum Near End Crosstalk (db/100m)
PSACR
Power Sum Attenuation to Crosstalk Ratio (dB/100m)
ACRF
Attenuation to Crosstalk Ratio - Far End (dB/100m)
PSACRF
Insertion Loss (dB/100m)
RL
Return Loss (dB)
Frequency IL, STD NEXT, STD ACR, STD PSNEXT, STD PSACR, STD ACRF, STD PSACRF, STD RL, STD
1.00 MHz 2.0 65.3 63.3 62.3 60.3 63.8 60.8 20.0
4.00 MHz 4.1 56.3 52.2 53.3 49.2 51.8 48.8 23.0
8.00 MHz 5.8 51.8 46.0 48.8 43.0 45.7 42.7 24.5
10.00 MHz 6.5 50.3 43.8 47.3 40.8 43.8 40.8 25.0
16.00 MHz 8.2 47.2 39.0 44.2 36.0 39.7 36.7 25.0
20.00 MHz 9.3 45.8 36.5 42.8 33.5 37.8 34.8 25.0
25.00 MHz 10.4 44.3 33.9 41.3 30.9 35.8 32.8 24.3
31.25 MHz 11.7 42.9 31.2 39.9 28.2 33.9 30.9 23.6
62.50 MHz 17.0 38.4 21.4 35.4 18.4 27.9 24.9 21.5
100.00 MHz 22.0 35.3 13.3 32.3 10.3 23.8 20.8 20.1

Material Specifications

Conductor Material Bare copper
Insulation Material Polyolefin
Jacket Material PVC

Environmental Specifications

Operating Temperature -20 °C to +60 °C (-4 °F to +140 °F)
Environmental Space Non-plenum

Packaging and Weights

Cable weight 32.740 kg/km | 22 lb/kft
Packaging Type Pull box

Regulatory Compliance/Certifications

Agency Classification
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant