Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

64624474-144MLT | O-144-LD-5X-M12BL/13G/PE/PA

Base Product: O-LD

  • Available in:
  • Asia
  • Australia/New Zealand

144 Core OM4 Outdoor Mini Loose Tube - Double Jacket

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Regional Availability Asia | Australia/New Zealand
Portfolio CommScope®
Product Type Fiber OSP cable
Product Series O-LN

General Specifications

Cable Type Stranded loose tube
Construction Type Non-armored
Subunit Type Gel-filled
Jacket Color Blue
Jacket Marking Meters
Subunit, quantity 12
Fibers per Subunit, quantity 12
Total Fiber Count 144

Dimensions

Buffer Tube/Subunit Diameter 1.35 mm | 0.053 in
Diameter Over Jacket 8.4 mm | 0.331 in

Representative Image

Click on image to enlarge.

Material Specifications

Jacket Material Nylon | PE

Mechanical Specifications

Minimum Bend Radius, loaded 220 mm | 8.661 in
Minimum Bend Radius, unloaded 110 mm | 4.331 in
Tensile Load, short term, maximum 2000 N | 449.618 lbf
Compression 20 N/mm | 114.203 lb/in
Compression Test Method IEC 60794-1-21 E3
Flex 25 cycles
Impact 1 N-m | 8.851 in lb
Impact Test Method IEC 60794-1-21 E4
Strain See long and short term tensile loads
Strain Test Method IEC 60794-1-21 E1
Twist 10 cycles
Twist Test Method IEC 60794-1-21 E7

Optical Specifications

Fiber Type OM4

Optical Specifications, Wavelength Specific

Attenuation, maximum 0.70 dB/km @ 1,300 nm | 2.50 dB/km @ 850 nm

Environmental Specifications

Installation temperature 0 °C to +50 °C (+32 °F to +122 °F)
Operating Temperature 0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F)
Environmental Space Buried | Underground (duct)
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penetration Test Method IEC 60794-1 F5C

Environmental Test Specifications

Temperature Cycle -10 °C to +60 °C (+14 °F to +140 °F)
Temperature Cycle Test Method IEC 60794-1-22 F1

Packaging and Weights

Cable weight 62 kg/km | 41.662 lb/kft

Product Classification

Regional Availability Asia | Australia/New Zealand
Portfolio CommScope®
Product Type Fiber OSP cable
Product Series O-LN

General Specifications

Cable Type Stranded loose tube
Construction Type Non-armored
Subunit Type Gel-filled
Jacket Color Blue
Jacket Marking Meters
Subunit, quantity 12
Fibers per Subunit, quantity 12
Total Fiber Count 144

Dimensions

Buffer Tube/Subunit Diameter 1.35 mm | 0.053 in
Diameter Over Jacket 8.4 mm | 0.331 in

Material Specifications

Jacket Material Nylon | PE

Mechanical Specifications

Minimum Bend Radius, loaded 220 mm | 8.661 in
Minimum Bend Radius, unloaded 110 mm | 4.331 in
Tensile Load, short term, maximum 2000 N | 449.618 lbf
Compression 20 N/mm | 114.203 lb/in
Compression Test Method IEC 60794-1-21 E3
Flex 25 cycles
Impact 1 N-m | 8.851 in lb
Impact Test Method IEC 60794-1-21 E4
Strain See long and short term tensile loads
Strain Test Method IEC 60794-1-21 E1
Twist 10 cycles
Twist Test Method IEC 60794-1-21 E7

Optical Specifications

Fiber Type OM4

Optical Specifications, Wavelength Specific

Attenuation, maximum 0.70 dB/km @ 1,300 nm | 2.50 dB/km @ 850 nm

Environmental Specifications

Installation temperature 0 °C to +50 °C (+32 °F to +122 °F)
Operating Temperature 0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature -20 °C to +70 °C (-4 °F to +158 °F)
Environmental Space Buried | Underground (duct)
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penetration Test Method IEC 60794-1 F5C

Environmental Test Specifications

Temperature Cycle -10 °C to +60 °C (+14 °F to +140 °F)
Temperature Cycle Test Method IEC 60794-1-22 F1

Packaging and Weights

Cable weight 62 kg/km | 41.662 lb/kft
Click on image to enlarge.

Product Specification

Product Specification