MPTA06BDBBNN-500M

  • Available in:
  • Europe

HELIAX® Power cable, with aluminum shield with quantity 6 x 10mm² , flame resistant CPR Class Dca. rated, 500 meters

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.
Features and Benefits
  • Available with different colors on demand

Product Classification

Regional Availability Europe
Portfolio CommScope®
Product Type Power cable
Product Brand HELIAX®
Ordering Note CommScope® non-standard product
Warranty For more information, please consult our Product Warranty guidelines

General Specifications

Application Remote radio head
Cable Type Power
Conductor Type, singles Stranded
Conductors, quantity 6
Jacket Color Black
Jacket Color, singles Blue | Brown
Outer Shield (Tape) Material Al/PET tape

Dimensions

Cable Length 500.024 m | 1640.5 ft
Diameter Over Jacket, maximum 17.983 mm | 0.708 in
Conductor Gauge 10 mm² class 5

Electrical Specifications

Safety Voltage Rating 600 V

Ordering Tree

Click on image to enlarge.

Material Specifications

Ground Wire Material Annealed aluminum wires
Insulation Material, singles Flame retardant PE
Jacket Material Flame retardant PE | Low Smoke Zero Halogen (LSZH)
Outer Shield (Braid) Coverage 100 %
Outer Shield (Tape) Material Al/PET tape

Environmental Specifications

Installation temperature -20 °C to +70 °C (-4 °F to +158 °F)
Operating Temperature -40 °C to +90 °C (-40 °F to +194 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Environmental Space Indoor/Outdoor
Jacket UV Resistance UV stabilized

Packaging and Weights

Cable weight 170.008 kg/km | 114.24 lb/kft

Product Classification

Regional Availability Europe
Portfolio CommScope®
Product Type Power cable
Product Brand HELIAX®
Ordering Note CommScope® non-standard product
Warranty For more information, please consult our Product Warranty guidelines

General Specifications

Application Remote radio head
Cable Type Power
Conductor Type, singles Stranded
Conductors, quantity 6
Jacket Color Black
Jacket Color, singles Blue | Brown
Outer Shield (Tape) Material Al/PET tape

Dimensions

Cable Length 500.024 m | 1640.5 ft
Diameter Over Jacket, maximum 17.983 mm | 0.708 in
Conductor Gauge 10 mm² class 5

Electrical Specifications

Safety Voltage Rating 600 V

Material Specifications

Ground Wire Material Annealed aluminum wires
Insulation Material, singles Flame retardant PE
Jacket Material Flame retardant PE | Low Smoke Zero Halogen (LSZH)
Outer Shield (Braid) Coverage 100 %
Outer Shield (Tape) Material Al/PET tape

Environmental Specifications

Installation temperature -20 °C to +70 °C (-4 °F to +158 °F)
Operating Temperature -40 °C to +90 °C (-40 °F to +194 °F)
Storage Temperature -40 °C to +80 °C (-40 °F to +176 °F)
Environmental Space Indoor/Outdoor
Jacket UV Resistance UV stabilized

Packaging and Weights

Cable weight 170.008 kg/km | 114.24 lb/kft
Click on image to enlarge.

Product Specification

Product Specification