APS-XT
Antenna Orientation and Location Sensing System
Features and Benefits
- Available as a retrofit to site-installed CommScope and Third Party antennas
- Monitors Azimuth, Tilt, Roll, Latitude, Longitude and Elevation
- Works with AISG 2.1 controllers as an Alignment Sensor Device and Geographic Location Sensor
- Works with AISG 2.0 controllers in RET emulation mode
- Verify Installations
- Long Term Monitoring
Specifications
Product Classification
Product Type | RET actuator |
General Specifications
AISG Input Connector | 8-pin DIN Male |
AISG Input Connector Quantity | 1 |
AISG Output Connector | 8-pin DIN Female |
AISG Output Connector Quantity | 1 |
Azimuth Note | Accuracy may be affected by installation environment and satellite visibility |
Azimuth, nominal | ±2.5° |
Color | Gray |
Elevation | ±5 m |
Latitude | ±5 m |
Longitude | ±5 m |
Roll | ±1° |
Tilt | ±1° |
Dimensions
Height | 99 mm | 3.898 in |
Width | 325 mm | 12.795 in |
Depth | 166 mm | 6.535 in |
Electrical Specifications
Input Voltage | 10–30 Vdc |
Boot Time | 15 s |
Boot Time Note | Exceeds AISG 2.0 and 2.1 requirements |
Electromagnetic Compatibility (EMC) | CFR 47 Part 15, Subpart B, Class A | EN 55022 | EN 55032 | EN 61000-4-2 | EN 61000-4-3 | EN 61000-4-4 | EN 61000-4-6 |
Interface Protocol Signal | RS-485 |
Lightning Surge Capability Test Method | IEC 61000-4-5 |
Lightning Surge Capability Waveform | 1.2/50 voltage and 8/20 current combination waveform |
Lightning Surge Test Mode | Common mode |
Power Consumption, maximum | 3 W |
Power Supply | AISG (compliant with AISG 2.1 ASD and GLS, exceeds AISG 2.0 RET) |
Protocol | 3GPP/AISG 2.0 compliant |
Material Specifications
Material Type | ASA |
Environmental Specifications
Operating Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
Relative Humidity | Up to 95%, non-condensing |
Climatic Sequence Test Method | IEC 60068-2-14 |
Cold Exposure Test Method | IEC 60068-2-1 |
Corrosion Test Method | IEC 60068-2-11, Test Condition Ka | IEC 60068-2-52, Test Condition Kb |
Damp Heat Exposure Test Method | IEC 60068-2-30, Test Condition Db |
Heat Exposure Test Method | IEC 60068-2-2 |
Ingress Protection Test Method | IEC 60529:2001, IP56 |
Packaged Product Shock Test Method | ASTM D4169 | GR-63-CORE, Section 4.1.1 |
Rain Simulation Test Method | IEC 60068-2-18, Test Condition Ra, Method 1 |
UV Resistance Test Method | IEC 60068-2-5, Test Condition B |
Vibration Test Method | ASTM D4169 | IEC 60068-2-6 |
Packaging and Weights
Weight, net | 1.5 kg | 3.307 lb |
Regulatory Compliance/Certifications
Agency | Classification |
CE | Compliant with the relevant CE product directives |
ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system |
ROHS | Compliant |
CHINA-ROHS | Below maximum concentration value |
UK-ROHS | Compliant |
Product Classification
Product Type | RET actuator |
General Specifications
AISG Input Connector | 8-pin DIN Male |
AISG Input Connector Quantity | 1 |
AISG Output Connector | 8-pin DIN Female |
AISG Output Connector Quantity | 1 |
Azimuth Note | Accuracy may be affected by installation environment and satellite visibility |
Azimuth, nominal | ±2.5° |
Color | Gray |
Elevation | ±5 m |
Latitude | ±5 m |
Longitude | ±5 m |
Roll | ±1° |
Tilt | ±1° |
Dimensions
Height | 99 mm | 3.898 in |
Width | 325 mm | 12.795 in |
Depth | 166 mm | 6.535 in |
Electrical Specifications
Input Voltage | 10–30 Vdc |
Boot Time | 15 s |
Boot Time Note | Exceeds AISG 2.0 and 2.1 requirements |
Electromagnetic Compatibility (EMC) | CFR 47 Part 15, Subpart B, Class A | EN 55022 | EN 55032 | EN 61000-4-2 | EN 61000-4-3 | EN 61000-4-4 | EN 61000-4-6 |
Interface Protocol Signal | RS-485 |
Lightning Surge Capability Test Method | IEC 61000-4-5 |
Lightning Surge Capability Waveform | 1.2/50 voltage and 8/20 current combination waveform |
Lightning Surge Test Mode | Common mode |
Power Consumption, maximum | 3 W |
Power Supply | AISG (compliant with AISG 2.1 ASD and GLS, exceeds AISG 2.0 RET) |
Protocol | 3GPP/AISG 2.0 compliant |
Material Specifications
Material Type | ASA |
Environmental Specifications
Operating Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
Relative Humidity | Up to 95%, non-condensing |
Climatic Sequence Test Method | IEC 60068-2-14 |
Cold Exposure Test Method | IEC 60068-2-1 |
Corrosion Test Method | IEC 60068-2-11, Test Condition Ka | IEC 60068-2-52, Test Condition Kb |
Damp Heat Exposure Test Method | IEC 60068-2-30, Test Condition Db |
Heat Exposure Test Method | IEC 60068-2-2 |
Ingress Protection Test Method | IEC 60529:2001, IP56 |
Packaged Product Shock Test Method | ASTM D4169 | GR-63-CORE, Section 4.1.1 |
Rain Simulation Test Method | IEC 60068-2-18, Test Condition Ra, Method 1 |
UV Resistance Test Method | IEC 60068-2-5, Test Condition B |
Vibration Test Method | ASTM D4169 | IEC 60068-2-6 |
Packaging and Weights
Weight, net | 1.5 kg | 3.307 lb |
Regulatory Compliance/Certifications
Agency | Classification |
CE | Compliant with the relevant CE product directives |
ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system |
ROHS | Compliant |
CHINA-ROHS | Below maximum concentration value |
UK-ROHS | Compliant |
Documentation & Downloads
Installation Instruction
Product Specification
Warranty
Installation Instruction
Product Compliance Documentation
Product Specification
Warranty
Other Ways to Browse